Temperature Calibration Equipment
01
Corporate Headquarters
2900 Saturn Street #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20230625
AccuMac AM1730
Secondary Reference PRT
OVERVIEW
The AM1730 series of Secondary Reference PRTs offers affordable reference probes for precision temperature mea-
surement and calibration both in the lab and in the eld. These PRTs feature an accuracy of <0.012°C and a short term
stability of <0.007°C.
To reach the best performance in stability and repeatability, the sensing element has been specially designed to protect
the platinum sensing wire from contamination at high temperatures. A unique supporting structure and lling material
provide the best balance among the hysteresis effect, mechanical shock and thermal shock performance. This high
performance probe fully meets the ITS-90 criteria for reference thermometers. Each probe comes standard with an ISO
17025 accredited calibration.
SPECIFICATIONS
Affordable Reference Probe
Accuracy: <0.012
°
C
at 0.01
°
C
Short-term Stability: <0.007
°
C
Temperature Range: -200
°
C to 420
°
C
Sheath Diameters Available in 2 Configurations: 1/4 inch
and 3/16 inch
Inconel™ Sheath to Withstand Harsh Environments
Fully Meets the ITS-90 Criteria for Reference Thermometers
ISO 17025 Accredited Calibration Included
AM1730-12 AM1730-9 AM1730-BEND
Temperature Range -200°C to 420°C -200°C to 420°C -200°C to 420°C
Nominal Resistance at 0.01°C 100 Ω
Temperature Coefcient 0.003925 Ω/Ω/°C
Calibrated Accuracy (k=2)
[1][2]
±0.025°C at -40°C
±0.015°C at 0.01°C
±0.035°C at 420°C
Long Term Drift at 0.01°C
[3]
<0.01°C at TPW after 100 hours at max temperature
Short Term Stability <0.007°C
Thermal Shock <0.005°C after 10 thermal cycles from minimum to maximum temperatures
Hysteresis ≤0.005°C
Self-heating 50 mW/°C
Response Time
[4]
9 seconds 6 seconds 9 seconds
Measurement Current 0.5 mA or 1 mA
Sensor Length 1.26 in (32 mm)
Sensor Location 0.12 in (3 mm) from tip
Insulation Resistance >1000 MΩ at room temperature
Sheath Material Inconel™
Sheath Dimensions
0.25 in (6.35 mm) (OD)
x 12 in (305 mm) (L)
0.188 in (4.775 mm) (OD)
x 9 in (228.6 mm) (L)
0.25 in (6.35 mm) (OD)
x 9.75 in (247.65 mm) vertical
x 4.5 in (114.3 mm) horizontal
External Leads Teon™ insulated copper wire, 4 leads, 6.5 feet (2 meters)
Handle Dimension
0.59 in (15 mm) (OD)
x 2.56 in (65 mm) (L)
0.39 in (10 mm) (OD)
x 1.97 in (50 mm) (L)
0.59 in (15 mm) (OD)
x 2.56 in (65 mm) (L)
Handle Temperature Range -50°C to 180°C
Calibration ISO 17025 accredited calibration
[1] Includes calibration and 100 hour drift.
[2] Probe calibration ranges may differ from probe temperature ranges (see Calibrated Accuracy for calibration ranges).
[3] Long-term drift rate is for reference only. It could be affected by such facts as handling, application, and maintenance, etc.
[4] For 63% response to step change in water moving at 1 meter per second.
Temperature Calibration Equipment
02
Corporate Headquarters
2900 Saturn Street #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20230625
ORDERING INFORMATION
Model Number
12 - 12 inch (305mm)
9 – 9 inch (228.6 mm)
BEND – 90
°
Bend
AM1730
12
ADT
AM1730
ADT – smart connection
SP – spade connection
Optional Accessories
Model Quantity Description Picture
9070 1 pc
Smart connector for reference
PRT for use with Additel
temperature products
9071 1 pc
Connector adapter from Additel
smart connector to 4-wire with
gold plated spades
9072
1 pc
Connector adapter from Additel
smart connector to 4-wire with
clamps
Note: Carrying case included (excludes -BEND probes)