Pressure Calibration Equipment
01
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20250414
Digital Pressure Modules
Additel 151
OVERVIEW
PRESSURE RANGE
ADT151 Module
Additel’s 151 pressure modules have been designed with exibility and efciency in mind and can easily be swapped
out as needed to meet changing needs and workloads. Higher pressure ADT151 modules cover two separate pressure
ranges and come with individual calibrations for each range. This allows for each module to accuracy cover a wide
range or pressure workloads. Also, each ADT151 is available in (3) different accuracy levels (0.02% FS, 0.01% FS and
0.01% of reading) to meet the demanding needs of our customers. Additel’s 151 pressure modules provide users with
the exibility and dependability end users have come to expect.
Pressure ranges to 15,000 psi (1,035 bar)
Accuracy of 0.02%FS, 0.01%FS or 0.01%RD
Fully temperature compensated accuracy
Two pressure ranges per module
Advanced temperature compensation
ISO 17025 accredited calibration and data included
Optional calibration fixture with software
The following tables mainly describes the range, accuracy, and precision of the ADT151 pressure modules. For
pressure modules of gauge pressure (GP) and differential pressure (DP) and compound pressure (CP), the zero
drift can be eliminated by regular zeroing of the device.The specifications are valid at ambient temperatures from
-10°C~50°C. We recommend that these pressure models be calibration annually. ADT151 module provides single-
range and dual-range, users can choose according to needs.
Precision: The error components include linearity, hysteresis, repeatability, resolution and temperature compensation.
Accuracy: The error components include linearity, hysteresis, repeatability, resolution, reference standard measurement
uncertainty, annual drift, temperature compensation, K=2.
Model
[1]
Absolute Pressure Range Accuracy
ADT151-BP (60~110) kPa ±22 Pa
ADT151-BPH (60~110) kPa ±10 Pa
[1] A barometric pressure module is optional for ADT773/ADT783/ADT793. After inserting the barometric pressure module, the
controller can be toggled to and from gauge and absolute pressure units.
BAROMETRIC MEASUREMENT SPECIFICATIONS
GP Pressure Module with Calibration Fixture BP Pressure Module with Calibration Fixture
02
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Email: sales@additel.com
Pressure Calibration Equipment
Rev # 20250414
Model
Range
Compound Gauge pressure
Media
Precision
[3]
(%FS)
Accuracy
[1] [4]
(%FS)
Burst Pressure
Suggested Controller
Compatibility
1st range 2nd range
GP15K
(0~15000) psi
(0~1035) bar
(0~6000) psi
(0~420) bar
G,L
0.004
(0.007)
0.01
(0.02)
1.3x ADT793
GP10K
(0~10000) psi
(0~700) bar
(0~5000) psi
(0~350) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT793
CP6K
(-15~6000) psi
(-1~420) bar
(-15~3000) psi
(-1~200) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT793
CP5K
(-15~5000) psi
(-1~350) bar
(-15~3000) psi
(-1~200) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT793
CP3.6K
(-15~3600) psi
(-1~250) bar
(-15~1500) psi
(-1~100) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT783-3.6K
CP3K
(-15~3000) psi
(-1~200) bar
(-15~1500) psi
(-1~100) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x
ADT783-3.6K
CP2K
(-15~2000) psi
(-1~140) bar
(-15~1000) psi
(-1~70) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT783-3.6K
CP1K
(-15~1000) psi
(-1~70) bar
(-15~500) psi
(-1~35) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x
ADT783-1K
ADT783-3.6K
CP500
(-15~500) psi
(-1~35) bar
(-15~300) psi
(-1~20) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x
ADT783-1K
ADT783-3.6K
CP300
(-15~300) psi
(-1~20) bar
(-15~150) psi
(-1~10) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x
ADT783-1K
ADT783-3.6K
CP150
(-15~150) psi
(-1~10) bar
(-15~60) psi
(-1~4) bar
G,L
0.004
(0.007)
0.01
(0.02)
1.3x ADT783-1K
CP100
(-15~100) psi
(-1~7) bar
(-15~50) psi
(-1~3.5) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT783-1K
CP50
(-15~50) psi
(-1~3.5) bar
(-15~30) psi
(-1~2) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT783-1K
CP35
(-15~35) psi
(-1~2.5) bar
(-15~15) psi
(-1~1) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT783-1K
CP30
(-15~30) psi
(-1~2) bar
(-15~15) psi
(-1~1) bar
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT783-1K
CP15
(-15~15) psi
(-1~1) bar
(-10~10) psi
(-0.7~0.7) bar
[2]
G,L
0.004
(0.007)
0.01
(0.02)
2x ADT783-1K
[1] For the full-scale accuracy, FS refers to the upper limit of the range - the lower limit of the range.
[2]The second range (-10~10)psi accuracy is 0.02%FS, the precision is 0.01%FS.
[3] Precision: the error components include linearity, hysteresis, repeatability, resolution, and temperature compensation.
[4] Accuracy: the error components include linearity, hysteresis, repeatability, resolution, reference standard measurement uncertainty, annual drift,
temperature compensation, K=2.
SPECIFICATIONS
Pressure Calibration Equipment
03
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20250414
Model
[3]
Differential Pressure
Measurement
Type
Pressure
Medium
Precision
[4]
(%FS)
Accuracy
[1]
[5]
(%FS)
Burst
Pressure
Static Pressure
Range
Suggested
Controller
Compatibility
1st range 2nd range
DP1K
(-400~1000) inH2O
(-1000~2500) mbar
(-400~400) inH2O
(-1000~1000) mbar
DP G 0.015 0.02
10000
mbar
1MPa ADT783-D
DP800
(-400~800) inH2O
(-1000~2000) mbar
(-400~400) inH2O
(-1000~1000) mbar
DP G 0.015 0.02
10000
mbar
1MPa ADT783-D
DP400
(-400~400) inH2O
(-1000~1000) mbar
(-200~200) inH2O
(-500~500) mbar
DP G 0.015 0.02 4000 mbar 1MPa
ADT783-D
ADT773
DP300
(-300~300) inH2O
(-700~700) mbar
(-150~150) inH2O
(-350~350) mbar
DP G 0.015 0.02 4000 mbar 400kPa
ADT783-D
ADT773
DP200
(-200~200) inH2O
(-500~500) mbar
(-100~100) inH2O
(-250~250) mbar
DP G 0.015 0.02 4000 mbar 400kPa
ADT783-D
ADT773
DP150
(-150~150) inH2O
(-350~350) mbar
(-100~100) inH2O
(-250~250) mbar
DP G 0.015 0.02 4000 mbar 400kPa
ADT783-D
ADT773
DP100
(-100~100) inH2O
(-250~250) mbar
(-50~50) inH2O
(-125~125) mbar
DP G 0.015 0.02 1000 mbar 100kPa
ADT783-D
ADT773
DP50
(-50~50) inH2O
(-125~125) mbar
(-30~30) inH2O
(-75~75) mbar
DP G 0.015 0.02 1000 mbar 100kPa
ADT783-D
ADT773
DP30
(-30~30) inH2O
(-75~75) mbar
(-20~20) inH2O
(-50~50) mbar
DP G 0.015 0.02 1000 mbar 100kPa
ADT783-D
ADT773
DP20
[2]
(-20~20) inH2O
(-50~50) mbar
(-10~10) inH2O
(-25~25) mbar
DP G 0.015 0.02 100 mbar 60kPa
ADT783-D
ADT773
DP10
[2]
(-10~10) inH2O
(-25~25) mbar
(-5~5) inH2O
(-10~10) mbar
DP G 0.015 0.02 100 mbar 60kPa ADT773
DP5
[2]
(-5~5) inH2O
(-10~10) mbar
(-2~2) inH2O
(-5~5) mbar
DP G 0.025 0.05 100 mbar 60kPa
ADT773
DP2
[2]
(-2~2) inH2O
(-5~5) mbar
(-1~1) inH2O
(-2.5~2.5) mbar
DP G 0.025 0.05 100 mbar 60kPa ADT773
[1] FS means upper range - lower range.
[2] Recommended calibration cycle 180 days.
[3] DP300 to DP1000 provides positive range, accuracy and precision specications continue to apply;
DP10 to DP150 provides a positive range with accuracy and precision specications of 0.02%FS and 0.015%FS, respectively;
DP2 to DP5 provides a positive range, with accuracy and precision specications of 0.05%FS and 0.025%FS, respectively.
[4] Precision: the error components include linearity, hysteresis, repeatability, resolution, and temperature compensation.
[5] Accuracy: the error components include linearity, hysteresis, repeatability, resolution, reference standard measurement uncertainty, annual drift,
temperature compensation, K=2.
04
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Email: sales@additel.com
Pressure Calibration Equipment
Rev # 20250414
High-precision Gauge Pressure Module Specifications
Model
Gauge
pressure
range
Absolute
Pressure
Range
[1]
Media
Precision
[3][4]
Accuracy
[2][5]
Burst
Pressure
Suggested Controller
Compatibility
GP15KM
(0~15000) psi
(0~1035) bar
(15~15015) psi
(0~1036) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
1.3x ADT793
GP10KM
(0~10000) psi
(0~700) bar
(15~10015) psi
(1~701) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x ADT793
CP6KM
(-15~6000) psi
(-1~420) bar
(0~6015) psi
(0~421) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x ADT793
CP5KM
(-15~5000) psi
(-1~350) bar
(0~5015) psi
(0~351) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x ADT793
CP3.6KM
(-15~3600) psi
(-1~250) bar
(0~3615) psi
(0~251) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x
ADT793
ADT783-3.6K
CP3KM
(-15~3000) psi
(-1~200) bar
(0~3015) psi
(0~201) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x
ADT793
ADT783-3.6K
CP2KM
(-15~2000) psi
(-1~140) bar
(0~2015) psi
(0~141) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x ADT783-3.6K
CP1.5KM
(-15~1500) psi
(-1~100) bar
(0~1515) psi
(0~101) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
1.3x ADT783-3.6K
CP1KM
(-15~1000) psi
(-1~70) bar
(0~1015) psi
(0~71) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x
ADT783-1K
ADT783-3.6K
CP500M
(-15~500) psi
(-1~35) bar
(0~515) psi
(0~36) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x ADT783-1K
ADT783-3.6K
CP300M
(-15~300) psi
(-1~20) bar
(0~315) psi
(0~21) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x
ADT783-1K
ADT783-3.6K
CP150M
(-15~150) psi
(-1~10) bar
(0~165) psi
(0~11) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
1.3x
ADT783-1K
ADT783-3.6K
CP100M
(-15~100) psi
(-1~7) bar
(0~115) psi
(0~8) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x ADT783-1K
CP50M
(-15~50) psi
(-1~3.5) bar
(0~65) psi
(0~4.5) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x ADT783-1K
CP35M
(-15~35) psi
(-1~2.5) bar
(0~50) psi
(0~3.5) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x ADT783-1K
CP30M
(-15~30) psi
(-1~2) bar
(0~45) psi
(0~3) bar
G,L
0.008% rdg or 0.004% FS
whichever is greater
0.01% rdg or 0.005% FS
whichever is greater
2x ADT783-1K
[1] Absolute pressure is achieved through the synthesis of the basic gauge pressure module and the optional atmospheric pressure module.
[2] The accuracy of the negative pressure part is equal to the accuracy of the positive pressure part, such as the maximum error of -15 psi is equal to the
maximum allowable error of 15 psi.
[3] FS refers to the positive range, and the accuracy of the negative pressure part is equal to that of the positive pressure part.
[4] Precision: the error components include linearity, hysteresis, repeatability, resolution, and temperature compensation.
[5] Accuracy: the error components include linearity, hysteresis, repeatability, resolution, reference standard measurement uncertainty, annual drift,
temperature compensation, K=2.
Pressure Calibration Equipment
05
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20250414
ORDERING INFORMATION
Model Number
ADT151
GP15K
01
Accuracy:
01 - 0.01% of full span
02 - 0.02% of full span
05 - 0.05% of full span
Additel 783 with ADT151 Pressure Modules
Accessories included
ISO 17025 accredited Calibration Certicate
Optional Accessories
Model
number
Description Picture
9054
Calibration fixture for ADT151
(Including adapter base w/ 1/4BSP male
fitting, RS232/power supply
cable, 9V adapter, calibration software)
GENERAL SPECIFICATIONS
Standard presicion High-precision
Model CPXX DPXX GPXX CPXM
Operating temperature
-10 °C to 50 °C (14 °F to 122 °F )
Storage temperature
-30°C to 70°C (-22°F to 158°F)
Relative humidity
10% to 95% RH,non-condensing
Pressure connection
(for external use only)
6 mm (O-ring,3*1.5-NBR70)
Enclosure
(for external use only)
Aluminum
Dimensions (Dia x H)
30 mm x 80 mm x 91mm(1.18” x 3.15” x 3.58”)
Weight
0.5 kg (1.1 lb)
Warranty
1 Year
Pressure range P/N:
See pressure range table